Emergency ward ultrasound: clinical audit on disinfection practices during routine and sterile examinations

Abstract : Context: In the emergency ward, where the use of ultrasound is common (including for sterile procedures), ward equipment is constantly exposed to high risks of microbiological contamination. There are no clear guidelines for disinfection control practices in emergency departments, and it is not known how emergency ward doctors follow good hygiene practices. Method: A multi-centre audit was conducted in 16 emergency services from Northern France regional hospitals, in form of a questionnaire. It was proposed to all emergency ward physicians. We excluded questionnaires when physicians mentioned that they did not use ultrasound on a daily basis. The questionnaire was designed using existing hygiene and ultrasound disinfection practices guidelines from varying French medical societies. It included three different clinical scenarios: (a) ultrasound on healthy skin, (b) on injured skin, and (c) ultrasound-guided punctures. All questions were closed-ended, with only one answer corresponding to the guidelines. We then calculated compliance rates for each question, each clinical situation, and an overall compliance rate for all the questions. Results: 104 questionnaires were collected, and 19 were excluded. For the 85 analysed questionnaires, the compliance rates were 60.4% 95% CI [56.4-64.7] for ultrasound on healthy skin, 70.9% 95% CI [66.3-76.1] on injured skin and 69.4% 95% CI [65.1-73.6] for ultrasound-guided punctures. The overall compliance rate for the compliance questions was 66.1% 95% CI [62.8-69.1]. Analysis of the questionnaires revealed severe asepsis errors, misuse of gel, ignorance of infection control practices to be applied in the context of ultrasound-guided puncture and exposure of the probe to body fluids. Conclusion: This study details areas for quality improvement in the disinfection of emergency ultrasound scanner use. Consequently, we propose a standardized protocol based upon the recommendations used for the questionnaire drafting, with a visual focus on the low compliance points that have been revealed in this audit. This protocol has been distributed to all the medical emergency services audited and included in the emergency resident's ultrasound learning program.
Type de document :
Article dans une revue
Liste complète des métadonnées

https://hal.sorbonne-universite.fr/hal-03127450
Contributeur : Gestionnaire Hal-Su <>
Soumis le : lundi 1 février 2021 - 15:12:23
Dernière modification le : jeudi 15 avril 2021 - 15:08:19

Fichier

s13756-021-00896-w.pdf
Publication financée par une institution

Identifiants

Citation

A. Andolfo, R. Maatoug, N. Peiffer-Smadja, C. Fayolle, K. Blanckaert. Emergency ward ultrasound: clinical audit on disinfection practices during routine and sterile examinations. Antimicrobial Resistance & Infection Control, 2021, 10 (1), pp.25. ⟨10.1186/s13756-021-00896-w⟩. ⟨hal-03127450⟩

Partager

Métriques

Consultations de la notice

351

Téléchargements de fichiers

92